Fixed Gas Detection Systems in Egypt

A fixed gas detection system watches an area around the clock and acts before a leak becomes a fire or a poisoning. Tetratech designs, supplies, installs and maintains complete systems with Sensitron, Tecnocontrol and Crowcon equipment.

What a system includes

  1. Detectors – one per risk point, chosen for the gas and the area (safe area or hazardous ATEX zone).
  2. Control panel – reads every detector, shows the levels and switches alarms and outputs at set thresholds. Sensitron MULTISCAN++ panels and addressable systems connect many detectors on one cable.
  3. Alarms – sounders and beacons inside and outside the room.
  4. Actions – gas shut-off solenoid valve, extraction fans, signal to the fire alarm or BMS.

Where detectors go

  • Natural gas (methane) is lighter than air: detectors near the ceiling, above the gas source.
  • LPG is heavier than air: detectors near the floor.
  • Carbon monoxide mixes with air: detectors at breathing height.
  • One detector covers a limited area, so large rooms and car parks need several. We size the layout from your drawings.

Standards we design to

  • EN 60079-29-1 for flammable gas detectors, and EN 45544 for toxic gas detectors.
  • ATEX / IECEx certified equipment in hazardous zones.
  • SIL-rated detectors where the safety study requires them.
  • EGAS and local authority requirements for gas installations.

Typical applications

Boiler rooms, commercial kitchens, factories, oil and gas sites, refrigeration machine rooms, battery charging rooms, laboratories, water and wastewater plants, and underground car parks.

How we work

Site survey → detector layout and proposal → supply → installation and wiring → commissioning with test gas → handover with certificates → periodic calibration (see Gas Detector Calibration).

See all fixed detectors and panels at gas-detection.net, or start from Gas Detectors in Egypt. Request a quote: +20 111 118 7661, +20 111 996 9655 or WhatsApp.

Frequently asked questions

How many gas detectors does a room need?

It depends on the gas, the room size and layout, and where gas could leak. We calculate it from your drawings during the survey.

Can the system shut off the gas automatically?

Yes. The control panel can close a gas solenoid valve and start ventilation when a detector reaches the alarm level.

Do you supply ATEX detectors for hazardous areas?

Yes, ATEX / IECEx certified detectors from Sensitron and Crowcon.

Can detectors connect to our BMS or fire alarm?

Yes, through relay outputs, 4–20 mA signals or Modbus, depending on the model.