Skip to searchSkip to main content

SENSIT® Gold G2

Introduction

SENSIT® GOLD G2 is a next generation instrument that is ideal for locating gas leaks and confined space applications. This instrument can also be used for inert gas operations to detect combustible gases in oxygen-free environments.

SENSIT® GOLD G2 can be configured for combustible gas readings in PPM, LEL and/or percent volume, as well as, a variety of toxic gases and oxygen.

SENSIT® GOLD G2 is
Accurate
Durable
Easy to Use
Easy to Maintain

Description

Introduction

SENSIT® GOLD G2 multi gas detector is a highly advanced instrument designed to locate gas leaks and use in confined spaces. It is suitable for detecting combustible gases in oxygen-free environments, making it ideal for inert gas operations.

The instrument can be configured for combustible gas readings in PPM, LEL and/or percent volume, and various toxic gases and oxygen.

DISPLAYS UP TO 4 GASES SIMULTANEOUSLY

SENSIT® GOLD G2 is extremely accurate, durable, and easy to use and maintain. It can display up to four gases simultaneously, including:

  • LEL (% volume and PPM optional)
  • oxygen, carbon monoxide
  • hydrogen sulfide
  • hydrogen cyanide (optional)

It also has selectable gas types, such as methane (natural gas) and propane.

Partial List of Gases Sensed

The instrument can sense a partial list of gases, such as:

  • Butane
  • Carbon Monoxide
  • Gasoline
  • Hydrogen Sulfide
  • Hydrogen Cyanide
  • Methane
  • Natural Gas
  • Oxygen
  • Propane

Product Specification
Data Sheets
Product Specification

Product Specification

roduct Specification

Size11.5” x 3” x 2.32” (29.2 x 7.6 x 5.9 cm)
Weight1.2 lb. (544 g)
Operating Temperature-4 to 104 F (-20 to 40° C)
Storage Temperature-25°C to +65°C (-13°F to +149°F)
Battery LifeAlkaline: Approximately 18 hrs. Continuous
Standard KitHard Carrying Case
3 "C" Batteries
Extra Sensor Cap
Choice of 2 Piece Barhole Probe or Confined Space Probe
Wrist Strap
T10 Allen Wrench
Instruction Manual

Additional Features

Barhole Test FeaturesPeak Readings
Sustained Readings
Timed Test
Adjustable Calibration RemindersCalibration Due
Calibration Over-Due (Shows at Start-up)
Gas Identification Alert Options"NSR" - Non-Standard Response
“NSC” - Combustible Other Than Gas Calibrated to (4-5% Volume)

Optional Features

Data logging Options100 Instant Event Saves
1600 Auto Log Saves
100 Bar Hole Tests

Sensor Specifications

TypeResolutionRangeAccuracy
PPM*1PPM or 10PPM0-10,000PPM±10%
LEL0.1% up to 2%0-100% LEL±10%
% NAT GAS0.1%5-100% GAS±5%
% Propane0.1%2.2-100% GAS±5%
O20.1%0-25%±0.2% or 10%**
CO1PPM0-2000PPM±5PPM or 5%**
H2S1PPM0-100PPM±2PPM or 5%**
HCN1PPM0-30PPM±1PPM or 5%**

*PPM Optional
**Whichever is greater

Data Sheets