Skip to searchSkip to main content

SENSIT® Gold G3

SENSIT® GOLD G3 makes gas detection faster and more accurate than ever. Designed for worker productivity, the SENSIT® GOLD G3 features improved durability, sensor and pump performance monitoring and unmatched data logging and mapping capabilities.

® GOLD G3 is ideal for locating above and below-ground gas leaks, confined space monitoring, pipeline purging, leak surveys, and other applications.

® GOLD G3 multi-gas detector can be configured with up to 5 sensors for combustible and toxic gases and oxygen.

Description

Introduction

Multi-Gas Leak Detector the, SENSIT® GOLD G3 is a top-of-the-line device that takes it to the next level. It offers advanced features that improve worker productivity and safety. Including enhanced durability, sensor, and pump performance monitoring. Data logging and mapping capabilities that are unparalleled in the industry. With these features, gas detection is faster, more accurate, and more efficient than ever.

DISPLAYS UP TO 5 GASES SIMULTANEOUSLY

The SENSIT® GOLD G3 detects up to 5 gases simultaneously, including combustible and toxic gases and oxygen. It provides detailed information on the amount and type of gas present, like Oxygen, Carbon Monoxide, Hydrogen Sulfide, and Hydrogen Cyanide. This device is useful for workers to respond accordingly. It can display readings in %Volume and PPM with an optional LEL for Methane and Propane.

STANDARD FEATURES
  • Intrinsically safe, with IP64 certification for water and dust protection.
  • Its durable rubberized housing ensures reliability in tough environments.
  • It also features a 2-speed pump for fast sampling and an audible tick for fast leak locating.
  • Additionally, it comes with a flashlight for low-light situations.
  • These features ensure the device is reliable and easy to use in various environments.
  • SENSIT® GOLD G3 has “smart” sensors with long life, multi-language support, LED warning light, Bluetooth, and an easy-to-read display.
  • With accurate and reliable readings on the job, you can stay safe and productive.
  • The device is also compatible with
    • SMART-CAL 360 for automatic calibration/bump testing
    • SMART-LINK 360 for downloading logs
    • and SERVICE 360 for firmware updates.
Applications

The Multi-Gas Leak Detector, the SENSIT® GOLD G3 is a versatile multi-gas leak detector. That detects and measures combustible gas leaks of carbon monoxide. It’s easy to use and maintain. Making it ideal for various applications such as gas leak surveys, emissions testing, and monitoring confined spaces. The detector provides workers precise data about the gases present, enabling them to respond quickly and keep everyone safe.

Certifications

Moreover, The SENSIT® GOLD G3 multi-gas detector is UL-certified. Ensuring that it meets the highest standards of safety and quality. With all of these advanced features and certifications, the SENSIT® GOLD G3 is a reliable and effective tool for any workplace that requires gas detection.

Product Specification
Data Sheets
Product Specification
Sensit Gold G3

Product Specification

Product Specification

SizeL-13 x W-3 x D-3.2 in (330 x 76 x 81 mm)
Weight2.3lbs (1.0kg)
Operating Temperature-4 to 122° F (-20 to 50° C)
Storage Temperature-4 to 140°F (-20 to 60° C)
Battery Life>20hrs Continuous with Rechargeable
Recharge Time10hrs Max
Recharge Temperature32°F to 104°F (0°C to 40°C)
Environmental ProtectionIP64
Display2.7” TFT LCD
Standard KitSoft-Sided, Padded Pouch
Vehicle/Desktop Charger
Wall Transformer or Vehicle Aux Cord
Rechargeable Battery
Extra Sensor Cap
Wrist Strap
Instruction Manual
Optional AccessoriesGPS with 3M Accuracy
Extension Adapter
Belt Clip
Carrying Strap (Additional Hardware Required)

Additional Features

Quick MenuTick
Barhole
Purge Test
Leak Search
Peak Mode
Stand By
CF Test
CO Test
Confined Space Mode
Inert Mode
Barhole Test FeaturesPeak Readings
Sustained Readings
30 Second Test Automatic Barhole Test Purge
Test Data Saved to Memory
Configurable Calibration RemindersNext Calibration Due
Last Calibration
Calibration Over-Due
Days Remaining Until Calibration Due
Calibration Required Lockout
Gas Specification“NSR” - Non-Standard Response
“NSC” - Non-Standard Combustible

Sensor Specifications

TypeTechnologyResolutionRangeAccuracy
LELSemiconductorVariable: 0.1% - 2.0% Increments0-100% LEL±10% or 1%LEL*
PPM*Semiconductor1 ppm or 10 ppm0 – 50,000 ppm±10% or 500ppm*
% NAT GASThermal Conductivity0.1%5 – 100% Methane±5%
PropaneThermal Conductivity0.1%2.2 – 100% Propane±5%
O2Electrochemical0.1%0-25%±0.2% or 10%**
COElectrochemical1PPM0-2,000PPM±5PPM or 5%**
H2SElectrochemical1ppm or 0.1ppm0-100PPM±2PPM or 5%**
HCNElectrochemical1ppm or 0.1ppm0-30PPM±1PPM or 5%**
SO2Electrochemical0.1ppm0-20PPM±1PPM or 10%**

*PPM Optional
**Whichever is greater


Data Sheets